Use and Care Manual

instructions, operation and maintenance of the water heater .

TURN OFF GAS TO THE APPLIANCE: Rotate the com -

bination gas control/thermostat knob counter-clockwise  to

the “OFF” position.

REMOVE JACKET DOOR: See Figure 1 or 2.

3. DISCONNECTION OF THERMOPILE, PILOT SUPPL Y

LINE, BURNER SUPPL Y TUBE AND PIEZO WIRING

FROM THE COMBINA TION GAS CONTROL : Locate

the thermopile connector on the combination gas control.

Carefully pull off the connector . Using a 7/16" open-end

wrench, disconnect the pilot supply line from the combination

gas control. Using a 3/4" open-end wrench, disconnect the

b u r n e r supply tube from the combination gas control. Locate

the piezo wire connector and disconnect it by pulling it apart.

See Figures 1 or 2 for the type of control your water heater is

equipped with..

NOTICE: The thr eads for connection of the burner supply

tube nut on LP combination gas controls ar e left-handed.

INST ALLA TION INSTRUCTIONS

(Honeywell Pilot Assembly Replacement Kit)

Read these instructions thor oughly and understand all steps and procedur es before

pr oceeding with the installation.