instructions, operation and maintenance of the water heater .
TURN OFF GAS TO THE APPLIANCE: Rotate the com -
bination gas control/thermostat knob counter-clockwise to
the “OFF” position.
REMOVE JACKET DOOR: See Figure 1 or 2.
3. DISCONNECTION OF THERMOPILE, PILOT SUPPL Y
LINE, BURNER SUPPL Y TUBE AND PIEZO WIRING
FROM THE COMBINA TION GAS CONTROL : Locate
the thermopile connector on the combination gas control.
Carefully pull off the connector . Using a 7/16" open-end
wrench, disconnect the pilot supply line from the combination
gas control. Using a 3/4" open-end wrench, disconnect the
b u r n e r supply tube from the combination gas control. Locate
the piezo wire connector and disconnect it by pulling it apart.
See Figures 1 or 2 for the type of control your water heater is
equipped with..
NOTICE: The thr eads for connection of the burner supply
tube nut on LP combination gas controls ar e left-handed.
INST ALLA TION INSTRUCTIONS
(Honeywell Pilot Assembly Replacement Kit)
Read these instructions thor oughly and understand all steps and procedur es before
pr oceeding with the installation.